The three main characteristics of a promotional platform:
â‘¢ The display method is simple and convenient for quick adjustment of display.
Promotion Desk Application Scope: Velcro Counter,Velcro Exhibition Table,Rectangle Pop Up Promotion Table,Foldable Aluminum Frame SUZHOU JH DISPLAY&EXHIBITION EQUIPMENT CO.,LTD , https://www.jh-snapframe.com
â‘ Strengthen the visual impact of product display: attract more customers' attention, enter the store, and make purchases.
â‘¡ Enhance the fullness of the product and give customers a sense of richness.
Solid structure, low cost, and durability. Easy to disassemble and carry, the promotional platform is suitable for various exhibitions, large stores, product promotions, and other activities. The structure is sturdy, and the product advertising display is quite atmospheric.
The ABS blister promotional platform is made of high-strength plastic material, with an ABS blister countertop. The surface texture is frosted, flawless, and more aesthetically pleasing. The bottom buckle design makes the entire promotional platform more stable and less prone to shaking.
Pulse electromagnetic valve installation precautions to ensure normal use
1, the best way to install electromagnetic pulse valve is perpendicular to the horizontal pipe, the coil up. In the premise does not agree, allow ± 30 ° tilt. Otherwise, normal use can not be guaranteed. 2, the solenoid valve nameplate parameters should be consistent with the actual use requirements. 3, the arrow on the solenoid valve body should be consistent with the media flow. 4, in order to ensure the normal use of the solenoid valve, please install oil-water separator in front of the solenoid valve. 5, in a hazardous environment to prevent sparks may lead to the occurrence of explosions and other accidents, the use of explosion-proof solenoid valve. 6, before installation, please thoroughly purge air bags and piping to prevent foreign matter damage to the diaphragm caused by the solenoid valve failure. 7, when the solenoid valve fails, in order to promptly isolated and easy maintenance, it is recommended to install bypass (bypass) device. 8, the electromagnetic pulse valve temporarily installed, can be stored at 0 ~ 40 ℃, relative humidity ≤ 80%, but without corrosive gases indoor rotor pump, as far as possible to avoid open storage. 9, after unpacking should first check the use of a single, the factory certificate, packing list is complete. And then check the list of product names, models are consistent, the control nameplate is consistent with the purchase order. If the defect or does not match, should promptly contact with the manufacturers ideas. More keyword search: Solenoid valve